Print Back
A Pressure Leak Test or Pressure Decay Leak Test involves pressurizing the coil, component or refrigeration circuit with dry air or nitrogen and monitoring for a pressure drop over a preset time period.
  • It is an automatic pass/fail test suitable for finding gross leaks, in the range of tens of ounces of refrigerant per year.
  • Pressure decay should be used as a preliminary test prior to Helium or Hydrogen Leak Testing.
  • Can replace water bath test but does not provide leak location; a tracer gas leak test such as Helium or Hydrogen/Nitrogen mix is required to locate leaks.
Tester PDHP
Unit of Measure
Items VTech PD10
VTech PD Series
Pressure Decay Leak Test Instrument
VTech 50 HP
VTech 50
Pressure Decay Leak Test System
VTech UNO
VTech UNO-H
Pressure Leak Test System
Pressure Decay Leak Test N/A Yes
# of parts/test N/A 1 or 2 N/A up to 4 N/A 1-4
Component Evacuation N/A Optional N/A Optional N/A Yes
Leak Location? N/A No